Introducing APAR Anushakti, our revolutionary electrical wire engineered with cutting-edge Electron Beam Technology (E-beam). This groundbreaking innovation isn’t just an improvement; it’s a leap forward in electrical safety and performance. APAR Anushakti wires boast a remarkable 50% increase in current-carrying capacity compared to conventional options, allowing your electrical systems to handle more power efficiently and reliably. What’s more, these wires offer enhanced resistance to higher temperatures, ensuring superior durability and peace of mind in even the most demanding environments. With its unmatched performance and eco-friendly manufacturing, APAR Anushakti is truly establishing itself as the safest house wire option in India, setting a new benchmark for electrical safety.
Low Smoke
Enhancing fire safety by reducing smoke emissions, protecting lives, and preserving critical infrastructure.
Zero Halogen
Minimizing environmental impact, ensuring safety, and promoting sustainable electrical systems
Current Carrying Capacity
50% more current carrying capacity*.
Short Circuit Protection
Max Short Circuit Temperature Rating 250° C.
Features & Advantages
In response to the growing demand for our E-beam technology-manufactured APAR Anushakti wires, we’ve expanded our product line to include HR FR LSH wires, specifically designed to address critical fire hazards. The acronym stands for Heat Retardant, Flame Retardant, Low Smoke, Zero Halogen, signifying their advanced safety features. These wires are engineered to resist the spread of flames, actively helping to prevent the escalation of fires in electrical installations and significantly reducing potential damage. This makes them an ideal choice for fire-resistant electrical wiring in both residential and commercial buildings, providing a crucial layer of protection.
50 Years – Powered by E-Beam Technology
Heat Resistant at 105° C
The insulation with a higher operating Temperature of 120° C.
Anti Termite
Effective defence against termites with advanced anti-termite solutions.
Flame Retardant
High Oxygen and Temperature Index make it fire retardant and self-extinguishing. It doesn’t catch fire on its own.
Melt Resistant
The insulation does not quickly melt while in contact with a hot object.
Very Low Leakage
Minimal leakage, maximizing efficiency and sustainability.
Energy Savings
Energy-efficient cable, powering sustainability with every connect.
Technical Characteristics & Standards
| Test | Specification Values |
|---|---|
| Temperature Index | ≥ 250 °C |
| Oxygen Index | > 29% |
| Smoke density (light absorption) | 75% |
| Acid gas generation | 20% |
| Service life years | > 50 Years |
Core: Single Core
Insulation: HR FR PVC
Length: 90 m, 100 m & 180 m
Colour: Red, Green, Blue, Black, White, Yellow (Available in custom colours)
| NOMINAL AREA OF COPPER CONDUCTOR | CONDUCTOR CONSTRUCTION | THICKNESS OF INSULATION (NOMINAL) | APPROX OVERALL DIAMETER | CONDUCTOR RESISTANCE (MAX) PER KM @20 C | IN CONDUIT / TRUNKING | UNENCLOSED-CLIPPED DIRECTLY TO SURFACE OR ON CABLE TRAY |
|---|---|---|---|---|---|---|
| Sq.mm | Nos / mm | mm | mm | Ohms | Amps | Amps |
| 0.75 / Class 5 | 24 / 0.2 | 0.6 | 2.20 | 26 | 11 | 16 |
| 1 / Class 2 | 7 / 0.43 | 0.7 | 2.70 | 18.1 | 16 | 24 |
| 1 / Class 5 | 32 / 0.2 | 0.6 | 2.40 | 19.5 | 16 | 24 |
| 1.5 / Class 2 | 7 / 0.53 | 0.7 | 3.00 | 12.1 | 20 | 32 |
| 1.5 / Class 5 | 30 / 0.25 | 0.7 | 2.85 | 13.30 | 20 | 32 |
| 2.5 / Class 2 | 7 / 0.67 | 0.8 | 3.60 | 7.41 | 27 | 44 |
| 2.5 / Class 5 | 50 / 0.25 | 0.8 | 3.50 | 7.98 | 27 | 44 |
| 4 / Class 2 | 7 / 0.85 | 0.8 | 4.10 | 4.61 | 36 | 58 |
| 4 / Class 5 | 56 / 0.3 | 0.8 | 4.0 | 4.95 | 36 | 58 |
| 6 / Class 2 | 7 / 1.04 | 0.8 | 4.70 | 3.08 | 47 | 74 |
| 6 / Class 5 | 84 / 0.3 | 0.8 | 4.50 | 3.30 | 47 | 74 |
Frequently asked questions
What are the key fire safety benefits of choosing APAR Anushakti HR FR LSH wires for my home or commercial building?
The APAR Anushakti HR FR LSH (Heat Resistant, Flame Retardant, Low Smoke, Zero Halogen) cable is specifically designed to maximize safety in case of an electrical fire. Unlike conventional wires, its advanced formulation resists the spread of flames, actively preventing the escalation of fires within your electrical installations. Crucially, in the event of a fire, these wires emit very low levels of smoke, significantly improving visibility for safe evacuation, and are halogen-free, meaning they do not release toxic or corrosive gases, safeguarding both human life and valuable property from chemical damage during combustion. This makes them the safest house wire option in India for enhanced fire protection.
How does APAR Anushakti's cutting-edge E-beam technology contribute to its superior performance and reliability?
APAR Anushakti HR FR LSH wires are manufactured using groundbreaking Electron Beam (E-beam) Technology. This innovative process structurally modifies the wire at a molecular level, leading to significantly enhanced properties compared to traditional wires. E-beam technology provides a remarkable 50% increase in current carrying capacity, allowing for greater electrical load handling without overheating. It also imparts superior heat resistance up to 105°C, makes the wire short-circuit resistant and melt-resistant, and ensures an exceptional service life of over 50 years. This advanced processing ensures unmatched durability, reduces energy leakage, and makes APAR Anushakti an incredibly reliable and energy-efficient cable for long-term electrical installations.
What does 'HR FR LSH' signify, and why is this combination important for household wiring and critical installations?
he acronym HR FR LSH stands for Heat Resistant, Flame Retardant, Low Smoke, Zero Halogen. Each component is vital for comprehensive electrical safety:
- HR (Heat Resistant): Ensures the wire can withstand higher operating temperatures (up to 105°C) without degradation.
- FR (Flame Retardant): Prevents the propagation of flames, meaning the wire won’t act as a conduit for fire spread.
- LSH (Low Smoke Zero Halogen): Crucial for human safety during a fire, as it vastly reduces harmful smoke emissions and eliminates toxic, corrosive gases, ensuring clearer escape routes and protecting electronic equipment from acid damage. This combination provides a multi-layered defense, making APAR Anushakti ideal for residential wiring, public buildings, hospitals, and any area where human safety during a fire emergency is paramount.
HR FR LSH