Skip to main content

  HR FR LSH

Anushakti-Fire-Protekt

Introducing APAR Anushakti, our revolutionary electrical wire engineered with cutting-edge Electron Beam Technology (E-beam). This groundbreaking innovation isn’t just an improvement; it’s a leap forward in electrical safety and performance. APAR Anushakti wires boast a remarkable 50% increase in current-carrying capacity compared to conventional options, allowing your electrical systems to handle more power efficiently and reliably. What’s more, these wires offer enhanced resistance to higher temperatures, ensuring superior durability and peace of mind in even the most demanding environments. With its unmatched performance and eco-friendly manufacturing, APAR Anushakti is truly establishing itself as the safest house wire option in India, setting a new benchmark for electrical safety.

Low Smoke Wires in India Icon

Low Smoke

Enhancing fire safety by reducing smoke emissions, protecting lives, and preserving critical infrastructure.

Zero Halogen Smoke Wires in India Icon

Zero Halogen

Minimizing environmental impact, ensuring safety, and promoting sustainable electrical systems

More Current Carrying Capacity Icon

Current Carrying Capacity

50% more current carrying capacity*.

Short Circuit Resistant cables manufacturer in India icon

Short Circuit Protection

Max Short Circuit Temperature Rating 250° C.

Features & Advantages

In response to the growing demand for our E-beam technology-manufactured APAR Anushakti wires, we’ve expanded our product line to include HR FR LSH wires, specifically designed to address critical fire hazards. The acronym stands for Heat Retardant, Flame Retardant, Low Smoke, Zero Halogen, signifying their advanced safety features. These wires are engineered to resist the spread of flames, actively helping to prevent the escalation of fires in electrical installations and significantly reducing potential damage. This makes them an ideal choice for fire-resistant electrical wiring in both residential and commercial buildings, providing a crucial layer of protection.

50 Years Life span wire Powered by E Beam Icon

50 Years – Powered by E-Beam Technology

Heat Resistant Cables Manufacturer in India Icon

Heat Resistant at 105° C

The insulation with a higher operating Temperature of 120° C.

Anti Termite wires manufacturer in India Icon

Anti Termite

Effective defence against termites with advanced anti-termite solutions.

Flame retardant Cable Manufacturer in India

Flame Retardant

High Oxygen and Temperature Index make it fire retardant and self-extinguishing. It doesn’t catch fire on its own.

Melt Resistant Cable Manufacturer in India

Melt Resistant

The insulation does not quickly melt while in contact with a hot object.

Very Low Leakage

Very Low Leakage

Minimal leakage, maximizing efficiency and sustainability.

Energy savings cable icon

Energy Savings

Energy-efficient cable, powering sustainability with every connect.

APAR Anushakti HR FR LSH - Safest wire in India

Technical Characteristics & Standards

Test Specification Values
Temperature Index ≥ 250 °C
Oxygen Index > 29%
Smoke density (light absorption) 75%
Acid gas generation 20%
Service life years > 50 Years

Core: Single Core
Insulation: HR FR PVC
Length: 90 m, 100 m & 180 m
Colour: Red, Green, Blue, Black, White, Yellow (Available in custom colours)

NOMINAL AREA OF COPPER CONDUCTOR CONDUCTOR CONSTRUCTION THICKNESS OF INSULATION (NOMINAL) APPROX OVERALL DIAMETER CONDUCTOR RESISTANCE (MAX) PER KM @20 C IN CONDUIT / TRUNKING UNENCLOSED-CLIPPED DIRECTLY TO SURFACE OR ON CABLE TRAY
Sq.mm Nos / mm mm mm Ohms Amps Amps
0.75 / Class 5 24 / 0.2 0.6 2.20 26 11 16
1 / Class 2 7 / 0.43 0.7 2.70 18.1 16 24
1 / Class 5 32 / 0.2 0.6 2.40 19.5 16 24
1.5 / Class 2 7 / 0.53 0.7 3.00 12.1 20 32
1.5 / Class 5 30 / 0.25 0.7 2.85 13.30 20 32
2.5 / Class 2 7 / 0.67 0.8 3.60 7.41 27 44
2.5 / Class 5 50 / 0.25 0.8 3.50 7.98 27 44
4 / Class 2 7 / 0.85 0.8 4.10 4.61 36 58
4 / Class 5 56 / 0.3 0.8 4.0 4.95 36 58
6 / Class 2 7 / 1.04 0.8 4.70 3.08 47 74
6 / Class 5 84 / 0.3 0.8 4.50 3.30 47 74

Frequently asked questions

What are the key fire safety benefits of choosing APAR Anushakti HR FR LSH wires for my home or commercial building?

The APAR Anushakti HR FR LSH (Heat Resistant, Flame Retardant, Low Smoke, Zero Halogen) cable is specifically designed to maximize safety in case of an electrical fire. Unlike conventional wires, its advanced formulation resists the spread of flames, actively preventing the escalation of fires within your electrical installations. Crucially, in the event of a fire, these wires emit very low levels of smoke, significantly improving visibility for safe evacuation, and are halogen-free, meaning they do not release toxic or corrosive gases, safeguarding both human life and valuable property from chemical damage during combustion. This makes them the safest house wire option in India for enhanced fire protection.

How does APAR Anushakti's cutting-edge E-beam technology contribute to its superior performance and reliability?

APAR Anushakti HR FR LSH wires are manufactured using groundbreaking Electron Beam (E-beam) Technology. This innovative process structurally modifies the wire at a molecular level, leading to significantly enhanced properties compared to traditional wires. E-beam technology provides a remarkable 50% increase in current carrying capacity, allowing for greater electrical load handling without overheating. It also imparts superior heat resistance up to 105°C, makes the wire short-circuit resistant and melt-resistant, and ensures an exceptional service life of over 50 years. This advanced processing ensures unmatched durability, reduces energy leakage, and makes APAR Anushakti an incredibly reliable and energy-efficient cable for long-term electrical installations.

What does 'HR FR LSH' signify, and why is this combination important for household wiring and critical installations?

he acronym HR FR LSH stands for Heat Resistant, Flame Retardant, Low Smoke, Zero Halogen. Each component is vital for comprehensive electrical safety:

  • HR (Heat Resistant): Ensures the wire can withstand higher operating temperatures (up to 105°C) without degradation.
  • FR (Flame Retardant): Prevents the propagation of flames, meaning the wire won’t act as a conduit for fire spread.
  • LSH (Low Smoke Zero Halogen): Crucial for human safety during a fire, as it vastly reduces harmful smoke emissions and eliminates toxic, corrosive gases, ensuring clearer escape routes and protecting electronic equipment from acid damage. This combination provides a multi-layered defense, making APAR Anushakti ideal for residential wiring, public buildings, hospitals, and any area where human safety during a fire emergency is paramount.